Description
English: Response of a LED-LDR optoisolator (vactrol) to a step change in LED current. Note that time scale is logarithmic!
  • Blue trace: response of a vactrol that was kept dark long enough. Owing to memory effect (common to all cadmium compounds), it overshoots steady-state resistance, initially going to a low "infinite dark" resistance (Rdh), then slowly recovers to steady-state target (black dashed line). Most cadmium compounds take hours to settle down completely (below measurement error), although some take weeks.
  • Red trace: response of a vactrol that was kept brightly illuminated. It overshoots in another direction, to a higher-than-expected value (Rlh).
  • Increase in resistance (red trace) is typically slower than decrease (blue trace).
Adapted from charts and textual information in PerkinElmer (2001). Photoconductive Cells and Analog Optoisolators (Vactrols®). pp. 7-11, 29, 34.
Date
Source Own work
Author East of Borschov

Licensing

Public domain I, the copyright holder of this work, release this work into the public domain. This applies worldwide.
In some countries this may not be legally possible; if so:
I grant anyone the right to use this work for any purpose, without any conditions, unless such conditions are required by law.

Captions

Add a one-line explanation of what this file represents

Items portrayed in this file

depicts

November 2010

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current16:10, 25 November 2010Thumbnail for version as of 16:10, 25 November 2010829 × 755 (47 KB)East of Borschov{{Information |Description={{en|1=Response of a LED-LDR optoisolator (vactrol) to a step change in LED current. Note that time scale is logarithmic! Blue trace: response of a vactrol that was kept dark long enough. It overshoots steady-state resistance,
The following pages on the English Wikipedia use this file (pages on other projects are not listed):